The organization mainly focused on analyzing the history of the construction of the building by examining its two main sections, floors, and walls.

Cause of the Collapse:

Following its extensive and detailed investigations, Walter J. Hickey Associates, Inc. presented a report on the possible cause for the collapse of the hotel. After making computations, it was discovered that the load on the cast iron column from the dead load alone was approximately 200,000 pounds in consideration of a minimal allowance for the corbelling action. However, a study revealed that the arching or corbelling effect of the C-Line Wall was only of slight importance. Due to the load, the bearing stress on the wall was estimated at around 7 to 8 times the permissible stress for a wall of good grade brick that has a good line cement mortar ("Investigation of Collapse," p. 45).

While the bearing stress at the opening...